BFOU and RFOU cables made to NEK TS 606

RFOU S101 offshore marine cable

The NEK TS 606 standard is for the most demanding marine and offshore applications where fire resistant (BFOU) or flame retardant (RFOU) cables are required. Our range of BFOU and RFOU cables are designed and manufactured in full compliance with the NEK TS 606 standard and approved by DNV.

Fire resistant and flame retardant

Highly suitable for use as power, lighting and control cords in both EX zones (0, 1 & 2), and all areas where high requirements for fire resistance exists.

Halogen-free for a safer environment

In the event of a fire, using halogen-free or Low Smoke Zero Halogen cables means there will be less smoke and no toxic fumes, ensuring the safety of crew and equipment.

Exceeding expectations

Demands on offshore cables often exceed the level of requirements in branch standards. Habia has the expertise and capabilities required to design and manufacture cable solutions in accordance with customer-specific demands based on the relevant IEC standards.

BFOU and RFOU cable features:

  • Mud resistant - meets both SHF2 and SHF2 MUD requirements
  • Temperature range of -50ºC to +135ºC (3500H)
  • Halogen-free materials - low smoke, zero halogen (LSZH)

Tailor-made for your needs

The BFOU and RFOU cables are available as standard, or as custom/hybrid versions on demand.

Explore more details below.

Product data sheets

BFOU P105

EPR insulated, HFS 125 XL (SHF2 MUD) sheathed, LSZH and fire resistant multicores to DNV GL, IEC 60092-353 and NEK TS 606. Standard multicore range from: - 1.0sqmm to 70sqmm (600V) - 2 core to 5 core - 1.0sqmm to 2.5sqmm (600V) - 2 core to 37 core - Screened - SHF2 MUD sheathed

RFOU P101

EPR insulated, HFS 125 XL (SHF2 MUD) sheathed, LSZH, flame retardant multicores to DNV GL, IEC 60092-353 and NEK TS 606. Standard multicore range from: - 1.0sqmm to 70sqmm (600V) - 2 core to 5 core - 1.0sqmm to 2.5sqmm (600V) - 2 core to 37 core - Screened - SHF2 MUD sheathed

RFOU S101

EPR insulated, HFS 125 XL (SHF2 MUD) sheathed, LSZH, flame retardant multipairs and multitriples to DNV GL, IEC 60092-376 and NEK TS 606. Standard multicore range from: - 0.75sqmm to 2.5sqmm (150V) - 1 pair to 32 pair - 1 triple to 24 triple - Individually screened - Armour / shield - SHF2 MUD sheathed

RFOU S102

EPR insulated, HFS 125 XL (SHF2 MUD) sheathed, LSZH, flame retardant multipairs and multitriples to DNV GL, IEC 60092-376 and NEK TS 606. Standard multicore range from: - 0.75sqmm to 2.5sqmm (150V) - 2 pair to 32 pair - 2 triple to 24 triple - Collectively screened - Armour / Shield - SHF2 MUD sheathed

Approvals

  • DNV GL (formerly Det Norske Veritas & Germanischer Lloyd)
  • Marine approved according to IEC 60092-376 and IEC 60092-353