Single wires

Our range of flexible ETFE, FEP, PFA & PTFE equipment wires are suitable for high temperature, low smoke, flame retardant applications. Halogen free options such as HFI 121 XL, HFI 140 XL, HFI 147 and HFI 150 enable us to offer cables in a wide variety of markets, whilst our manufacturing capabilities stretch from 36 AWG ultra thin wires to 400 sq. mm power cores and everything in between.

Product data sheets

ETFE (22759)

ETFE insulated cores, flame retardant, low smoke generation, high chemical resistance, based on MIL-W-22759/16-19 Standard core range from: - 30 AWG to 4 AWG (600V)

ETFE (French Norm)

ETFE insulated cores, flame retardant, low smoke generation, high chemical resistance, according to NF C 93-524 Standard core range from: - 30 AWG to 12 AWG (600V)

ETFE (Habia Standard)

ETFE insulated cores, flame retardant, low smoke generation, high chemical resistance Standard core range from: - 28 AWG to 26 AWG (160V) - 30 AWG to 20 AWG (250V) - 0.5sqmm to 1.0sqmm (300V) - 1.5sqmm to 6sqmm (450V) - 32 AWG to 240sqmm (600V) - 32 AWG to 2 AWG (1000V)

FEP (Habia Standard)

FEP insulated cores, flame retardant, low smoke generation, high chemical resistance Standard core range from: - 0.25sqmm to 0.75sqmm (250V) - 30 AWG to 26 AWG (300V) - 24 AWG to 6sqmm (600V) - 0.25sqmm to 95sqmm (1000V) - 26 AWG to 24 AWG (2000V) - 22 AWG to 16 AWG (2500V) - 1.5sqmm (3000V) - 14 AWG to 6sqmm (5000V)

FEP (NEMA HP-4)

FEP insulated cores, flame retardant, low smoke generation, high chemical resistance, based on NEMA HP-4 Standard core range from: - 32 AWG to 0.75sqmm (250V) - 32 AWG to 8 AWG (600V) - 32 AWG to 1 AWG (1000V)

HFI 121 XL

HFI 121 XL insulated cores, halogen free, flame retardant, low smoke generation Standard core range from: - 0.5sqmm to 150sqmm (600V)

HFI 140

HFI 140 insulated cores, halogen free, flame retardant, low smoke generation, approved to and based on Defence Standard 61-12 Part 18 Approved core range from: - 30 AWG to 10sqmm (600V) Standard core range from: - 0.5sqmm to 2.5sqmm (600V)

HFI 147

HFI 147 insulated cores, halogen free, flame retardant, low smoke generation Standard core range from: - 30 AWG to 12 AWG (600V)

HFI 150

HFI 150 insulated cores, halogen free, flame retardant, low smoke generation Standard core range from: - 30 AWG to 50sqmm (600V)

PFA

PFA insulated cores, flame retardant, low smoke generation, high chemical resistance Standard core range from: - 32 AWG to 20 AWG (300V) - 32 AWG to 10 AWG (600V) - 32 AWG to 6 AWG (1000V)

PTFE (BS 3G 210)

PTFE insulated cores, flame retardant, low smoke generation, high chemical resistance, approved to BS 3G 210 Approved core range from: - 32 AWG to 20 AWG (300V) - 32 AWG to 18 AWG (600V)

PTFE (French Norm)

PTFE insulated cores, flame retardant, low smoke generation, high chemical resistance, based on NF C 93-523 Standard core range from: - 32 AWG to 20 AWG (250V) - 32 AWG to 12 AWG (600V) - 32 AWG to 12 AWG (1000V)

PTFE (Habia Standard)

PTFE insulated cores and wire wrap wires, flame retardant, low smoke generation, high chemical resistance Standard core range from: - 36 AWG to 26 AWG (160V) - 0.5sqmm (250V) - 30 AWG to 26 AWG (300V) - 24 AWG to 2.5sqmm (600V) - 0.5sqmm to 10sqmm (1000V)

PTFE (NEMA HP-3)

PTFE insulated cores, flame retardant, low smoke generation, high chemical resistance, based on NEMA HP-3 Standard core range from: - 32 AWG to 20 AWG (250V) - 32 AWG to 10 AWG (600V) - 32 AWG to 6 AWG (1000V)

TPS 130

TPS 130 insulated cores, halogen free Standard core range from: - 26 AWG to 2.5sqmm (300V)

TWI 205

TWI 205 insulated cores, flame retardant, low smoke generation, high chemical resistance Standard core range from: - 32 AWG to 16 AWG (250V) - 32 AWG to 10 AWG (600V) - 26 AWG to 10 AWG (1000V)